Displaying 76 - 100 of 199

Report TitleMonthEnvironmentYearIncident TypeDetonator TypeLocation of incident/near missIncident NotesTime of the dayIncident InformationWeather ConditionsDamage to Property/Equipment?LTIWas the incident/near-miss following a misfire/misrun?If yes, how many people were involved?Operation TypeFatalitiesIf yes, how many fatalities?Learnings and Best Practices (if any):
Incident 09/01/1998 – 1SepIncidenttransportPakistan

Lost 6 Detos -

no
Incident 01/01/1998 – 1JanOffshoreIncidentwell siteUSA

surface detonation of gun -

yes1
Incident 01/01/1998 – 2JanoffshoreIncidentwell siteUSA

armed tubing cutter fell from 32' height and detonated. -

no

Cutter stuck in side door entry sub, wireline came out of head and fell

Incident 01/01/1998 – 3JanlandIncidentgun loadingUSA

Deto cord low ordered when cut with a twin bladed cutter tool -

no

Non-SOP

Incident 07/01/1997 – 1JulIncidentwell siteUSA

Unknown - Explosive device discharge on surface

Unknown, newspaper clipping

Incident 07/01/1997 – 2JulIncidentwell siteNigeria

TCP off depth detonation -

no

o-ring leaked pressure to closed chamber under the IRDV actuating the HDF

Incident 01/01/1997 – 1JanIncidentwell siteSyria

Low Order of cord while being cut -

yes1

Improper cutting technique and tool

Incident 01/01/1997 – 2JanlandIncidentwell siteUSA

Tubing Cutter detonated on surface after misrun - No details available. Cutter misfired. Then later on surface it fired. Newspaper Clipping only. No details

yes11
Incident 01/01/1997 – 3JanIncidentmanufacturingUSA

shaped charge low order - Banging charges together to clean out loose explosive

yes1

Non-SOP

Incident 11/01/1996 – 1NovChoose not to answerLandIncidentWell SiteTEXAS

Public Domain OSHA Report: Summary Nr: 200210185 Event: 1996 Four Employees Injured When Struck By Flying Shrapnel

At approximately 3:00 p.m., Employees #1 through #4 were perforating a well that was under pressure. The third time the gun was fired inside the lubricator and the pressure was released, the lubricator came apart. The shrapnel exploded below to the ground and the lubricator took off with the debris, striking the workers. Employees #1 through #4 sustained multiple injuries and were hospitalized.

Choose not to answerUnknownNo commentFour Injured PersonsChoose not to answerYes
Incident 09/01/1996 – 1SepIncidentwell siteUSA

Surface detonation putting head on armed gun -

yes31

Non-SOP

Incident 04/01/1996 – 1AprIncidentwell siteArgentina

Surface Detonation putting head on gun after misrun -

yes33

Non-SOP

Incident 01/01/1995 – 1JanIncidentwell siteUSA

misrun on gamma ray -

1
Incident 10/01/1994 – 1OctIncidentdisposalUSA

Unknown - Burning explosives

Burn to explosion

Incident 08/01/1994 – 1AugIncidentgun loadingAngola

Open-face perforator - Low order, dropping of shaped charge

Impact

Incident 05/01/1994 – 1MayIncidentmanufacturingUSA

detonation whilst pressing explosives -

no
Incident 04/01/1994 – 1AprIncidentgun loadingUSA

Loading shop detonation of TCP guns -

yes41

pinched deto cord - rough handling

Incident 01/01/1994 – 1JanlandIncidentwell siteUSA

Explosive stuck in tubing detonated on surface. (slick line) - Explosives charge ran in on slick line. It stuck. Pulled tubing to retrieve it. It was shallower than expected. Exploded when tubing was broke apart

2
Incident 01/01/1994 – 2JanIncidentwell siteUSA

Tubing cutter - Tubing cutter discharge on surface

Sheared across azide detonator

Incident 01/01/1994 – 3JanOffshoreIncidentwell siteUSA

jet cutter detonated on surface after misrun -

yes31
Incident 01/01/1994 – 4JanIncidentwell siteCanada

Unknown - Tool (?) went off on surface

Unknown

Incident 01/01/1994 – 5JanlandIncidentwell siteUSA

select fire gun with single barrel detonated while sitting on trailer with wireline attached -

no

unknown

Incident 01/01/1994 – 6JanIncidentwell siteUSA

pressure testing in lubricator - pressure testing Swing Jet gun at 110,000 psi

no

pressure collapse of capsule charges

Incident 01/01/1994 – 7JanIncidentmanufacturing testingUSA

Zinc charges in test pit - Fire at shaped charge manufacturer

Heat produced by zinc fragments

Incident 01/01/1994 – 8JanIncidentmanufacturingUSA

Power charges - Fire at shaped charge manufacturer

Unknown

Report TitleMonthEnvironmentYearIncident TypeDetonator TypeLocation of incident/near missIncident NotesTime of the dayIncident InformationWeather ConditionsDamage to Property/Equipment?LTIWas the incident/near-miss following a misfire/misrun?If yes, how many people were involved?Operation TypeFatalitiesIf yes, how many fatalities?Learnings and Best Practices (if any):