Displaying 51 - 75 of 199

Report TitleMonthEnvironmentYearIncident TypeDetonator TypeLocation of incident/near missIncident NotesTime of the dayIncident InformationWeather ConditionsDamage to Property/Equipment?LTIWas the incident/near-miss following a misfire/misrun?If yes, how many people were involved?Operation TypeFatalitiesIf yes, how many fatalities?Learnings and Best Practices (if any):
Incident 01/01/2003 – 1JanlandIncidentwell siteCanada

setting tool deployed at surface - After logging operation, powered up not knowing that setting tool was attached.

No

Non-SOP

Incident 01/01/2003 – 2JanlandIncidentmanufacturingUSA

waste material used in manufacturing process caught fire in magazine -

no

improper storate

Incident 01/01/2003 – 3JanlandIncidentgun loadingUSA

attempting to download bullet gun when barrel fired -

no

applying heat to gun, barrel dried out powder (after wash-out attempted) gun fired

Incident 01/01/2003 – 4JanoffshoreIncidentdownholeAustralia

Gun fired downhole while tractoring. - Recovering from misrun, tractor operator changed electrical boards, making shooting line disconnect inoperative. When the tractor was powered downhole, voltage was induced onto the shooting line. The protection unit below the tractor had lost its ground through vibration, failing to block tractor voltage to the gun. The gun fired off depth.

no

tractor malfunction and protection unit failed

Incident 11/01/2001 – 1NovIncidentWell SiteUSA

Surface low order , gun in riser, pressure testing exceeded rating -

No comment

Non-SOP

Incident 07/01/2001 – 1JulIncidentgun loadingUSA

Open-face perforator - Low order, dropping of shaped charge

Impact

Incident 07/01/2001 – 2JullandIncidentgun loadingUSA

Charge initiated when dropped while loading expendable gun. -

yes1

mechanical impact of one charge against another

Incident 01/01/2001 – 1JanoffshoreIncidentwell siteUSA

Core gun initiated in rat hole - Stray voltage applied to wirline during rigging
operation. One core discharged in the rat hole.

No

Non-sop

Incident 01/01/2001 – 2JanLandIncidentwell siteUSA

Surface detonation of select fire gun - Employee tried to remove detonator from side
arming sub by inserting pocket knife . Pressure was applied to detonator

yes3

employee applied pressure to detonator

Incident 12/01/2000 – 1DecLandIncidenttransportCanada

Commercial Carrier (freight company) truck burned to the ground along with our shipment of explosives -

no
Incident 10/01/2000 – 1OctlandIncidentwell siteUSA

Single shaped charge detonated on surface during a coil tubing conveyed perforating job. Few details available - Few details available. The field is typically done shot by shot.

yes1

Unknown

Incident 10/01/2000 – 2OctlandIncidenttransportUSA

Two carrier perforating guns with detonators were lost as crew returned from well site. Never found -

no

Non-SOP

Incident 09/01/2000 – 1SepOffshoreIncidentwell siteUSA

Coil Tubing deployed tubing puncher detonated in riser during pressure test. Firing head shear pins had been broken during string makeup using incorrect components. -

no

Non-SOP

Incident 01/01/2000 – 1JanIncidentwell siteS. America

Perforating gun - Perforating gun discharge on surface

Miscommunication, power on panel

Incident 01/01/2000 – 2JanIncidentmanufacturing testingUSA

Shaped charge - Shaped charge initiation

Unknown

Incident 01/01/2000 – 3JanlandIncidentdownholeUSA

2-7/8" gun auto detonated downhole - Perforating engineer assumed temperature and selected RDX detonator. Temperature downhole was higher and deto auto detonated causing gun to fire before getting on depth.

no

Incorrect detonator selected for temperature of well

Incident 10/01/1999 – 1OctlandIncidentwell siteUSA

Gun detonated on surface (mechanical firing mech.) - Accidentally fired a gun on surface. It had a single charge but many port plugs. The fireing mechanism was a mechanical jar

yes1
Incident 10/01/1999 – 2OctLandIncidentwell siteUSA

Gun went off at surface. (Mechanical slick line jar) 1 shot, several port plugs

yes1

Non-SOP

Incident 09/01/1999 – 1SepIncidentwell siteCanada

Surface Detonation putting head on gun after misrun -

yes11

Non-SOP

Incident 09/01/1999 – 2SepIncidentmanufacturing testingUSA

Perforating guns - Fire at shaped charge manufacturer

Insufficient barrier

Incident 04/01/1999 – 1AprIncidentmanufacturingUSA

Shaped charge detonation - Employee applied pressure to remove stuck charge
from die body

yes1

Non Sop

Incident 03/01/1999 – 1MarchIncidenttransportBangladesh

Lost explosives in shipment -

no
Incident 01/01/1999 – 1JanIncidenttransport

lost strip gun off truck -

no
Incident 01/01/1999 – 2JanlandIncidentmanufacturingUSA

dropped charge in bucked causing deflagration -

yes1

pinched explosive

Incident 01/01/1999 – 3JanIncidentmanufacturingUSA

QC shot detonated unexpectedly -

no

stray voltage

Report TitleMonthEnvironmentYearIncident TypeDetonator TypeLocation of incident/near missIncident NotesTime of the dayIncident InformationWeather ConditionsDamage to Property/Equipment?LTIWas the incident/near-miss following a misfire/misrun?If yes, how many people were involved?Operation TypeFatalitiesIf yes, how many fatalities?Learnings and Best Practices (if any):